1,223 research outputs found

    Intensity-Based Registration of Freehand 3D Ultrasound and CT-scan Images of the Kidney

    Full text link
    This paper presents a method to register a pre-operative Computed-Tomography (CT) volume to a sparse set of intra-operative Ultra-Sound (US) slices. In the context of percutaneous renal puncture, the aim is to transfer planning information to an intra-operative coordinate system. The spatial position of the US slices is measured by optically localizing a calibrated probe. Assuming the reproducibility of kidney motion during breathing, and no deformation of the organ, the method consists in optimizing a rigid 6 Degree Of Freedom (DOF) transform by evaluating at each step the similarity between the set of US images and the CT volume. The correlation between CT and US images being naturally rather poor, the images have been preprocessed in order to increase their similarity. Among the similarity measures formerly studied in the context of medical image registration, Correlation Ratio (CR) turned out to be one of the most accurate and appropriate, particularly with the chosen non-derivative minimization scheme, namely Powell-Brent's. The resulting matching transforms are compared to a standard rigid surface registration involving segmentation, regarding both accuracy and repeatability. The obtained results are presented and discussed

    Groupwise Multimodal Image Registration using Joint Total Variation

    Get PDF
    In medical imaging it is common practice to acquire a wide range of modalities (MRI, CT, PET, etc.), to highlight different structures or pathologies. As patient movement between scans or scanning session is unavoidable, registration is often an essential step before any subsequent image analysis. In this paper, we introduce a cost function based on joint total variation for such multimodal image registration. This cost function has the advantage of enabling principled, groupwise alignment of multiple images, whilst being insensitive to strong intensity non-uniformities. We evaluate our algorithm on rigidly aligning both simulated and real 3D brain scans. This validation shows robustness to strong intensity non-uniformities and low registration errors for CT/PET to MRI alignment. Our implementation is publicly available at https://github.com/brudfors/coregistration-njtv

    Prescribing practices of primary-care veterinary practitioners in dogs diagnosed with bacterial pyoderma

    Get PDF
    Concern has been raised regarding the potential contributions of veterinary antimicrobial use to increasing levels of resistance in bacteria critically important to human health. Canine pyoderma is a frequent, often recurrent diagnosis in pet dogs, usually attributable to secondary bacterial infection of the skin. Lesions can range in severity based on the location, total area and depth of tissue affected and antimicrobial therapy is recommended for resolution. This study aimed to describe patient signalment, disease characteristics and treatment prescribed in a large number of UK, primary-care canine pyoderma cases and to estimate pyoderma prevalence in the UK vet-visiting canine population

    Nonlinear Markov Random Fields Learned via Backpropagation

    Full text link
    Although convolutional neural networks (CNNs) currently dominate competitions on image segmentation, for neuroimaging analysis tasks, more classical generative approaches based on mixture models are still used in practice to parcellate brains. To bridge the gap between the two, in this paper we propose a marriage between a probabilistic generative model, which has been shown to be robust to variability among magnetic resonance (MR) images acquired via different imaging protocols, and a CNN. The link is in the prior distribution over the unknown tissue classes, which are classically modelled using a Markov random field. In this work we model the interactions among neighbouring pixels by a type of recurrent CNN, which can encode more complex spatial interactions. We validate our proposed model on publicly available MR data, from different centres, and show that it generalises across imaging protocols. This result demonstrates a successful and principled inclusion of a CNN in a generative model, which in turn could be adapted by any probabilistic generative approach for image segmentation.Comment: Accepted for the international conference on Information Processing in Medical Imaging (IPMI) 2019, camera ready versio

    A Longitudinal Method for Simultaneous Whole-Brain and Lesion Segmentation in Multiple Sclerosis

    Full text link
    In this paper we propose a novel method for the segmentation of longitudinal brain MRI scans of patients suffering from Multiple Sclerosis. The method builds upon an existing cross-sectional method for simultaneous whole-brain and lesion segmentation, introducing subject-specific latent variables to encourage temporal consistency between longitudinal scans. It is very generally applicable, as it does not make any prior assumptions on the scanner, the MRI protocol, or the number and timing of longitudinal follow-up scans. Preliminary experiments on three longitudinal datasets indicate that the proposed method produces more reliable segmentations and detects disease effects better than the cross-sectional method it is based upon

    Rhizome Severing Increases Root Lifespan of Leymus chinensis in a Typical Steppe of Inner Mongolia

    Get PDF
    Root lifespan is an important trait that determines plants' ability to acquire and conserve soil resources. There have been several studies investigating characteristics of root lifespan of both woody and herbaceous species. However, most of the studies have focused on non-clonal plants, and there have been little data on root lifespan for clonal plants that occur widely in temperate grasslands.We investigated the effects of rhizome severing on overall root lifespan of Leymus chinensis, a clonal, dominant grass species in the temperate steppe in northern China, in a 2-year field study using modified rhizotron technique. More specifically, we investigated the effects of rhizome severing on root lifespan of roots born in different seasons and distributed at different soil depths. Rhizome severing led to an increase in the overall root lifespan from 81 to 103 days. The increase in root lifespan exhibited spatial and temporal characteristics such that it increased lifespan for roots distributed in the top two soil layers and for roots born in summer and spring, but it had no effect on lifespan of roots in the deep soil layer and born in autumn. We also examined the effect of rhizome severing on carbohydrate and N contents in roots, and found that root carbohydrate and N contents were not affected by rhizome severing. Further, we found that root lifespan of Stipa krylovii and Artemisia frigida, two dominant, non-clonal species in the temperate steppe, was significantly longer (118 d) than that of L. chinensis (81 d), and this value became comparable to that of L. chinensis under rhizome severing (103 d).We found that root lifespan in dominant, clonal L. chinensis was shorter than for the dominant, non-clonal species of S. krylovii and A. frigida. There was a substantial increase in the root lifespan of L. chinensis in response to severing their rhizomes, and this increase in root lifespan exhibited temporal and spatial characteristics. These findings suggest that the presence of rhizomes is likely to account for the observed short lifespan of clonal plant species in the temperate steppe

    Discordance in diagnosis of osteoporosis using spine and hip bone densitometry

    Get PDF
    BACKGROUND: Diagnostic discordance for osteoporosis is the observation that the T-score of an individual patient varies from one key measurement site to another, falling into two different diagnostic categories identified by the World Health Organization (WHO) classification system. This study was conducted to evaluate the presence and risk factors for this phenomenon in a large sample of Iranian population. METHODS: Demographic data, anthropometric measurements, and risk factors for osteoporosis were derived from a database on 4229 patients referred to a community-based outpatient osteoporosis testing center from 2000 to 2003. Dual-energy X-ray absorptiometry (DXA) was performed on L1–L4 lumbar spine and total hip for all cases. Minor discordance was defined as present when the difference between two sites was no more than one WHO diagnostic class. Major discordance was present when one site is osteoporotic and the other is normal. Subjects with incomplete data were excluded. RESULTS: In 4188 participants (3848 female, mean age 53.4 ± 11.8 years), major discordance, minor discordance, and concordance of T-scores were seen in 2.7%, 38.9% and 58.3%, respectively. In multivariate logistic regression analysis, older age, menopause, obesity, and belated menopause were recognized as risk factors and hormone replacement therapy as a protective factor against T-score discordance. CONCLUSION: The high prevalence of T-score discordance may lead to problems in interpretation of the densitometry results for some patients. This phenomenon should be regarded as a real and prevalent finding and physicians should develop a particular strategy approaching to these patients

    The Main Belt Comets and ice in the Solar System

    Get PDF
    We review the evidence for buried ice in the asteroid belt; specifically the questions around the so-called Main Belt Comets (MBCs). We summarise the evidence for water throughout the Solar System, and describe the various methods for detecting it, including remote sensing from ultraviolet to radio wavelengths. We review progress in the first decade of study of MBCs, including observations, modelling of ice survival, and discussion on their origins. We then look at which methods will likely be most effective for further progress, including the key challenge of direct detection of (escaping) water in these bodies

    Identifying quality improvement intervention publications - A comparison of electronic search strategies

    Get PDF
    Abstract Background The evidence base for quality improvement (QI) interventions is expanding rapidly. The diversity of the initiatives and the inconsistency in labeling these as QI interventions makes it challenging for researchers, policymakers, and QI practitioners to access the literature systematically and to identify relevant publications. Methods We evaluated search strategies developed for MEDLINE (Ovid) and PubMed based on free text words, Medical subject headings (MeSH), QI intervention components, continuous quality improvement (CQI) methods, and combinations of the strategies. Three sets of pertinent QI intervention publications were used for validation. Two independent expert reviewers screened publications for relevance. We compared the yield, recall rate, and precision of the search strategies for the identification of QI publications and for a subset of empirical studies on effects of QI interventions. Results The search yields ranged from 2,221 to 216,167 publications. Mean recall rates for reference publications ranged from 5% to 53% for strategies with yields of 50,000 publications or fewer. The 'best case' strategy, a simple text word search with high face validity ('quality' AND 'improv*' AND 'intervention*') identified 44%, 24%, and 62% of influential intervention articles selected by Agency for Healthcare Research and Quality (AHRQ) experts, a set of exemplar articles provided by members of the Standards for Quality Improvement Reporting Excellence (SQUIRE) group, and a sample from the Cochrane Effective Practice and Organization of Care Group (EPOC) register of studies, respectively. We applied the search strategy to a PubMed search for articles published in 10 pertinent journals in a three-year period which retrieved 183 publications. Among these, 67% were deemed relevant to QI by at least one of two independent raters. Forty percent were classified as empirical studies reporting on a QI intervention. Conclusions The presented search terms and operating characteristics can be used to guide the identification of QI intervention publications. Even with extensive iterative development, we achieved only moderate recall rates of reference publications. Consensus development on QI reporting and initiatives to develop QI-relevant MeSH terms are urgently needed
    • …
    corecore